The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 12 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The mid range model DT4261, is an exceptional support tool with multifaceted functionality designed to help analyze a variety of issues and boost work efficiency.
CAT IV 600 V, CAT III 1000 V Key Features • ±0.15% DC V basic accuracy • Helping personnel analyze issues in the field • Boost work efficiency with digitalization (Excel® Direct Input Function) • Ensuring safety by preventing erroneous test lead insertion (terminal shutters) • Stop worrying about losing test lead caps • Excellent dust and water resistance (compliant with the IP54 international standard) | Model No. (Order Code)
![]() |
![]() |
Helping personnel analyze issues in the field
Harmonic measurementWhen combined with GENNECT Cross (*1), you can perform simple harmonic analysis. Applications include harmonic measurement of power conditioners for solar systems and problem analysis of power supply systems.See here for details about GENNECT Cross Problems that can be caused by harmonics
・ Equipment burn-out and destruction due to overheating
|
---|---|
![]() |
Wireless communication capability for even greater convenience Wireless supportWhen the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.See details about Wireless Adapter Z3210 |
![]() |
Excel® Direct Input Function (*2)
Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®. |
![]() |
Prevents incorrect current measurementFuse check functionWhen switching from the clamp function to the current function, a fuse disconnection check is automatically performed. This allows the user to know if the fuse is broken before current measurement, which prevents erroneous measurement. |
![]() |
Ensuring safety by preventing erroneous test lead insertionTerminal shuttersDue to the current terminal’s low impedance, measuring voltage after erroneously inserting a test lead into the current terminal will cause the fuse to blow. The DT4261’s terminal shutters are linked to the instrument’s rotary switch such that they block access to test lead terminals that aren’t being used, making it physically impossible to insert a lead into the wrong terminal. |
![]() |
Stop worrying about losing test lead caps Test Lead L9300 incorporate integrated caps for greater convenience and safety. The design lets you change the measurement category simply by sliding the test lead’s protective finger guard. You no longer have to worry about losing caps! |
![]() |
Multifaceted functionality and performance for a variety of tasks
・ Ability to withstand being dropped onto concrete from a height of 1 m (drop-proof design)
|
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
DC Voltage range | 600.0 mV to 1000 V, 5 rangesBasic accuracy: ±0.15% rdg. ±2 dgt. |
---|---|
AC Voltage* range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHzBasic accuracy 40 Hz - 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
LoZ V | 600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHzBasic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt. |
DC Current range | 600.0 mA to 10.00 A, 3 rangesBasic accuracy: ±0.5% rdg. ±3 dgt. |
AC Current range | 600.0 mA to 10.00 A, 3 rangesBasic accuracy 40 Hz - 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less)Frequency characteristics: 40 Hz to 1 kHz |
AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
Continuity Check | Continuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V |
Voltage frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)Basic accuracy: ±0.1% rdg. ±1 dgt. |
Current frequency range | 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)Basic accuracy: ±0.1% rdg. ±1 dgt. |
Other functions | Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed) |
Display | Main and sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 times/s) |
Power supply | LR6 (AA) alkaline batteries × 3, Continuous operating time: 130 hr. (without Z3210 installed), 70 hr. (with Z3210 installed and using wireless communications) |
Dimensions and mass | 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D, 480 g (16.9 oz.) (with test leads holder and batteries) |
Accessories | Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1 |
Catalog: DIGITAL MULTIMETER DT4261 | Download PDF | English |